Frequency Converters

Frequency Converters

We use cookies 🍪
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Learn more in our Privacy Policy.

45 KVA Single Phase Frequency Converter 50Hz To 60Hz

45 KVA Single Phase Frequency Converter 50Hz To 60Hz
45 KVA Single Phase Frequency Converter 50Hz To 60Hz
45 KVA Single Phase Frequency Converter 50Hz To 60Hz
45 KVA Single Phase Frequency Converter 50Hz To 60Hz
Free Shipping
45 KVA Single Phase Frequency Converter 50Hz To 60Hz
45 KVA Single Phase Frequency Converter 50Hz To 60Hz
45 KVA Single Phase Frequency Converter 50Hz To 60Hz
45 KVA Single Phase Frequency Converter 50Hz To 60Hz
45 KVA Single Phase Frequency Converter 50Hz To 60Hz
from Save -8%
$10,791.13
$11,690.00
Ex Tax: $10,791.13
  • Stock: In Stock
  • Model: HZTOHZ-G10
  • Weight: 1.00
  • SKU: HZTOHZ-G10

Available Options

Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.

45 kVA solid state pure sine wave AC power single phase frequency converter, converting fixed power frequency 50/60 Hz to variable frequency, up to 400Hz. By using this frequency converter, you can convert single phase 110V (120V) 60Hz to 220V (230V, 240V) 50Hz (additional step-up transformer required), also can change single phase 220V (230V, 240V) 50Hz to 110V (120V) 60Hz by a single device.

Specification

ModelHZ-50-1145
Capacity45kVA
Dimension900*750*1200mm
Weight320 kg
InputVoltage1 Phase 2 Wire: 110V/120V, 220V/230V/240V ± 10% (option *)
Frequency50 Hz, 60 Hz or 400 Hz ± 5%
OutputVoltage, current110V Setting (Low grade): 0-150V, 375A
220V Setting 0-300V (High grade): 0-300V, 188A
Load stabilization Rate≤±1%
Frequency50Hz, 60Hz up to 400Hz adjustable
Note:
-When the output is 400Hz, the load capacity can only reach 50% of the rated capacity.
-When the output is ≤120Hz, the load capacity can reach 100% of the rated value.
-You can just adjust converter output frequency in the range (40-400Hz) for 400Hz option.
Frequency Stability≤±0.01%
Harmonic DistortionPure Sine Wave ≤2%
Frequency meter4 digit, digital frequency meter, resolution 0.1Hz/Step
Voltmeter4 digit, digital voltage meter, resolution 0.1V
Ammeter4 digit, digital ammeter, resolution 0.1A
Watt meter4 digit, digital Watt meter, resolution 0.1W
ProtectionWith overload, short circuit, over temperature
Instantaneous power failure protection and alarm device
Working EnvironmentTemperature0 - 40 deg.℃
Humidity0 - 90% (Non condensation)
Warranty18 months

* The input voltage is factory selected.

Tips: Is it harmful if I running a motor at higher frequency power?
Most of the rotating devices using AC power supplies will not result in a hum if the frequency is above 10-15Hz. The speed of an AC motor is directly to the frequency and therefore at low frequencies the speed will be less. Modern power systems work at a constant frequency and the change in frequency cannot be more than 2%, i.e 50Hz can become at the most 49Hz, 60Hz at the most 59Hz, not less. Very often in good power systems, the frequency will be very close to 50 Hz/ 60 Hz unless there is a heavy load demand which cannot be met at a given time. It is mandatory that the frequency of AC power systems be maintained close to the 50Hz or 60Hz as the case may be. Again the high frequency component in power converters (particularly rectifiers which convert AC to DC depends on the type of rectifier. Full wave rectifiers the ripple frequency will be double the supply frequency, in three phase full wave 6 times and six phase full wave 12 times etc. Harmonics due to SMPS and PWM (pulse width modulated) systems, it will be much higher. The effect of these higher harmonics will not be felt by lighting systems in any case. Frequency of the flickering of lamps that can be perceived by human eyes will be much lower than power supply frequency.

Write a review

Note: HTML is not translated!
Rating
Bad Good

Builder in Product TAB

NEW! Since Journal 3.2, the much improved T.A.B (Tabs Accordion Blocks) system supports the page builder inside the tab content. Unlimited Blocks, Tabs or Accordions with any HTML content or the builder interface (supporting custom rows/columns/modules) can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules. Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities.