1hp variable frequency drive, single phase to three phase VFD, 220V AC.
Specification:
| Basics | Model | GK3000-2S0007 |
| Capacity | 1 hp (0.75 kW) | |
| Shipping weight | 2 kg | |
| Dimension | 142*85*113 mm | |
| I/O Feature | Rated current | 4 A |
| Input voltage | 1 phase 220~240V AC | |
| Input frequency | 50Hz/ 60Hz | |
| Output voltage | 3 phase AC 0~input voltage | |
| Output frequency | 0.00~400.00Hz | |
| Over load capacity | 150% of rated current for 1 minute, 180% of rated current for 3 seconds | |
| Control Feature | Control mode | V/F control; Sensorless vector control; |
| Communication | RS485 | |
| Speed regulation | 1:100 | |
| Start torque | 150% of rating torque at 1 Hz | |
| Speed control accuracy | ≤±0.5% of rating synchronous speed | |
| Frequency precision | Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% | |
| Frequency resolution | Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz | |
| Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% | |
| Interior PID controller | Be convenient to make closed-loop system | |
| Automatic energy save running | Optimize V/F curve automatically based on the load to realize power save running | |
| Automatic voltage regulation (AVR) | Can keep constant output voltage when power source voltage varies. | |
| Automatic current limiting | Limit running current automatically to avoid frequent over-current which will cause trip | |
| Environment | Enclosure rating | IP 20 |
| Temperature | –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5% | |
| Humidity | 5%-95%, without condensation | |
| Altitude | ≤1000m; VFD will be derated if above 1000m | |
| Impingement and oscillation | Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g) | |
| Store environment | –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight |
Tips: Considerations of selecting a VFD
When you use a Variable Frequency Drive (VFD), you need not worry about initial inrush, as its starting current will be only 100% of full load current. But this is not the main criteria for VFD selection. You have to find out the nature of load ie whether it is a constant load torque or variable load torque.
Nominal current demand will tell you the size required for the VFD selection but also you need to look at the application requirement for features. Proper torque control considerations, proper protection from the applications environment and harmonics too. Reaching out to a trained rep from a distributor of quality VFDs is best.
As those astute applications, there is not enough information.
1) What is the load? (CT or VT)
2) What is the voltage of the motor?
3) What is the duty cycle (how many starts/ stops per hour)
4) Are there any unusual operating conditions?
With this information, most VFD manufacturers should begin to address your application. REMEMBER, more info is always better that too little. Also you can follow this selection guide.