Specification:
| Basics | Model | GK3000-4T0022G/ GK3000-2T0022G |
| Capacity | 3 hp (2.2 kW) | |
| Shipping weight | 3 kg | |
| Dimension | 230*118*153 mm | |
| I/O Feature | Rated current | 5.1A at 380V ~ 480V, 9A at 220V ~ 240V |
| Input voltage | 3 phase 220V /380V /480V AC ±15% (Optional) | |
| Input frequency | 50Hz/ 60Hz | |
| Output voltage | 3 phase AC 0~input voltage | |
| Output frequency | 0.00~400.00Hz | |
| Over load capacity | 150% of rated current for 1 minute, 180% of rated current for 3 seconds | |
| Control Feature | Control mode | V/F control; Sensorless vector control; |
| Communication | RS485 | |
| Speed regulation | 1:100 | |
| Start torque | 150% of rating torque at 1 Hz | |
| Speed control accuracy | ≤±0.5% of rating synchronous speed | |
| Frequency precision | Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% | |
| Frequency resolution | Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz | |
| Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% | |
| Interior PID controller | Be convenient to make closed-loop system | |
| Automatic energy save running | Optimize V/F curve automatically based on the load to realize power save running | |
| Automatic voltage regulation (AVR) | Can keep constant output voltage when power source voltage varies. | |
| Automatic current limiting | Limit running current automatically to avoid frequent over-current which will cause trip | |
| Environment | Enclosure rating | IP 20 |
| Temperature | –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5% | |
| Humidity | 5%-95%, without condensation | |
| Altitude | ≤1000m; VFD will be derated if above 1000m | |
| Impingement and oscillation | Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g) | |
| Store environment | –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight |
Tips: VFD derating on altitude & temperature
While derating variable frequency drives (VFD) for altitude varies from manufacturer to manufacturer, as long as you are de-rating the VFD to meet the environment (temperature & altitude) you really shouldn't have a problem finding a VFD. I use a factor of 1% per every 328 feet above 3280 feet. Using that method, you will need to oversize the VFD by 20% to properly work over 10,000 feet, for example, you should go to a 5hp VFD instead of a 3hp VFD for that altitude. That, of course, doesn't account for the extreme cold temperatures which will be a problem, in such condition the operating and storage temperatures can be overcome by proper thermal management like putting a heater into the enclosure of the VFD. The storage temperature is about 20 degrees F lower that what is recommended by most VFD manufacturers but it may be tolerated.