200 hp VFD, 160 kW heavy duty three phase 240V, 420V, 480V variable frequency drive.
Specification:
| Basics | Model | GK3000-4T1600G/ GK3000-2T1600G |
| Capacity | 200 hp (160 kW) | |
| Shipping weight | 180 kg | |
| Dimension | 1440*600*399 mm | |
| I/O Feature | Rated current | 304A at 380V ~ 480V, 585A at 220V ~ 240V |
| Input voltage | Three phase 240V /420V /480V AC ±15% (Optional) | |
| Input frequency | 50Hz/ 60Hz | |
| Output voltage | Three phase AC 0~input voltage | |
| Output frequency | 0.00~400.00Hz | |
| Over load capacity | 150 % of rated current for 1 minute, 200 % of rated current for 1 seconds | |
| Control Feature | Control mode | V/F control; Sensorless vector control; |
| Communication | RS485 | |
| Speed regulation | 1:100 | |
| Start torque | 150% of rating torque at 1 Hz | |
| Speed control accuracy | ≤±0.5% of rating synchronous speed | |
| Frequency precision | Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% | |
| Frequency resolution | Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz | |
| Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% | |
| Interior PID controller | Be convenient to make closed-loop system | |
| Automatic energy save running | Optimize V/F curve automatically based on the load to realize power save running | |
| Automatic voltage regulation (AVR) | Can keep constant output voltage when power source voltage varies. | |
| Automatic current limiting | Limit running current automatically to avoid frequent over-current which will cause trip | |
| Environment | Enclosure rating | IP 20 |
| Temperature | –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5% | |
| Humidity | 5%-95%, without condensation | |
| Altitude | ≤1000m; VFD will be derated if above 1000m | |
| Impingement and oscillation | Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g) | |
| Store environment | –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight |
Tips: How does a VFD work?
The AC grid power is converted into DC and then the DC is converted back into AC via electronic gates at the cycles and voltage needed to make the AC motor run at the desired speed. The controlling of these gates is done with an electronic controller that is powered from the variable frequency drive (VFD) using a switcher power supply.
Variable Frequency Drives can be used for a variety of things when it comes to induction motors. Example: soft starting, torque control, speed adjustment etc. These VFDs are able to control the speed of an induction motor using the electrical frequency. This VFD is expensive but surely do a lot more than traditional motor starters, in terms of monitoring and more controls.