300 Hp (220 KW) VFD, 3 Phase 240V, 415V, 460V
Why buy from us?
Lorem Ipsum is simply dummy text of the printing and typesetting industry.
Ask a Question About This Product
- Stock: In Stock
- Model: HZTOHZ-G69
- Weight: 1.00
- SKU: HZTOHZ-G69
Available Options
300 hp VFD, 220 kW VFD option for 240V, 415V, 460V etc.
Specification:
| Basics | Model | GK3000-4T2200G/ GK3000-2T2200G |
| Capacity | 300 hp (220 kW) | |
| Shipping weight | 180 kg | |
| Dimension | 1440*600*399 mm | |
| I/O Feature | Rated current | 426A at 380V ~ 480V, 820A at 220V ~ 240V |
| Input voltage | Three phase 240V /415V /460V AC ±15% (Optional) | |
| Input frequency | 50Hz/ 60Hz | |
| Output voltage | Three phase AC 0~input voltage | |
| Output frequency | 0.00~400.00Hz | |
| Over load capacity | 150 % of rated current for 1 minute, 200 % of rated current for 1 seconds | |
| Control Feature | Control mode | V/F control; Sensorless vector control; |
| Communication | RS485 | |
| Speed regulation | 1:100 | |
| Start torque | 150% of rating torque at 1 Hz | |
| Speed control accuracy | ≤±0.5% of rating synchronous speed | |
| Frequency precision | Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% | |
| Frequency resolution | Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz | |
| Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% | |
| Interior PID controller | Be convenient to make closed-loop system | |
| Automatic energy save running | Optimize V/F curve automatically based on the load to realize power save running | |
| Automatic voltage regulation (AVR) | Can keep constant output voltage when power source voltage varies. | |
| Automatic current limiting | Limit running current automatically to avoid frequent over-current which will cause trip | |
| Environment | Enclosure rating | IP 20 |
| Temperature | –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5% | |
| Humidity | 5%-95%, without condensation | |
| Altitude | ≤1000m; VFD will be derated if above 1000m | |
| Impingement and oscillation | Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g) | |
| Store environment | –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight |
Tips: Benefits of Variable Frequency Drive over Star/Delta starting
On variable torque loads, power has a squared/cubed relationship to speed, so running the load at 60% speed requires between 21% and 36% of the power to run at 100% speed. On constant torque loads, power is directly proportional to speed, so 50% speed only requires 50% power. There are significant energy savings to be realized. Variable frequency drives (VFDs) also offer a soft start delivering 150 - 200% FLT at 0 to full speed with excellent current control so there are no hard start inrush current starts, particularly needed on weak power systems. Star/Delta starting is a reduced voltage method, unfortunately this also reduces torque in a squared relationship and therefore still allows 300 - 600% FL current, with resultant system voltage dips if network regulation is poor. No reduced voltage start method can compare with a VFD which maintains maximum motor air gap flux in a constant ratio of V/Hz, hence low current, high torque. Even soft starters (also reduced voltage method) are inferior if high dynamic torque control is needed.